Verified — all release criteria met
released
Certificate of analysis
BPC-157 + TB-500 Blend
Lot CP-BPCTBBU3-2605B · 10 mg + 10 mg
99.90 %
HPLC purity
Spec ≥ 99.0 %
91.1 %
Net peptide content
By amino acid analysis
< 0.21
Endotoxin (EU/mg)
Spec < 5.0 EU/mg
Provenance
- Testing laboratory
- Aurum Bioanalytics
- Accreditation
- ISO/IEC 17025:2017
- Country of synthesis
- United States
- Manufactured
- Apr 25, 2026
- Release tested
- May 4, 2026 (5 months ago)
- Retest date
- Apr 24, 2028
Assay results
Every line the release panel ran for this lot, with the method, the acceptance criterion and the measured value — not a pass mark alone.
| Method | Parameter | Specification | Result | |
|---|---|---|---|---|
| RP-HPLC (UV 214 nm) | Purity (area %) | ≥ 99.0 % | 99.90 % | Pass |
| LC-MS (ESI+) | Identity — observed mass | Conforms to reference | Conforms | Pass |
| Amino acid analysis | Net peptide content | ≥ 80.0 % | 91.1 % | Pass |
| Karl Fischer | Water content | ≤ 8.0 % | 2.67 % | Pass |
| Ion chromatography | Residual TFA | ≤ 1.0 % | 0.20 % | Pass |
| LAL kinetic chromogenic | Bacterial endotoxin | < 5.0 EU/mg | < 0.21 EU/mg | Pass |
| USP <71> membrane filtration | Sterility | No growth | No growth | Pass |
| Visual / USP <790> | Appearance | White to off-white cake, free of visible particulates | Conforms | Pass |
| RP-HPLC (multi-peak resolving gradient) | BPC-157 — purity in finished vial | ≥ 99.0 % | 99.40 % | Pass |
| RP-HPLC (multi-peak resolving gradient) | TB-500 — purity in finished vial | ≥ 99.0 % | 99.40 % | Pass |
Handling for this lot
- Appearance
- White lyophilised cake
- Storage
- -20 °C lyophilised; 2–8 °C reconstituted for up to 30 days
- Reconstitution
- Single reconstitution serves both components. The certificate states the measured mass ratio so you can calculate each component's concentration exactly.
Other lots of BPC-157 + TB-500 Blend
Compare batch to batch. Consistency across lots is a stronger signal than any single certificate.
Research use only. This certificate describes material supplied strictly for laboratory research. It is not a drug, food, cosmetic or medical device, has not been evaluated by the FDA, and is not intended for human or veterinary administration of any kind.