Skip to content
Third-party HPLC + mass spec on every lot
Verified — all release criteria met
releasedCurrent lot

Certificate of analysis

GHK-Cu + BPC-157 + TB-500 Blend

Lot CP-GHKBPCRW-2607A · 50 mg + 10 mg + 10 mg

99.33 %

HPLC purity

Spec ≥ 98.0 %

88.4 %

Net peptide content

By amino acid analysis

< 0.83

Endotoxin (EU/mg)

Spec < 5.0 EU/mg

Provenance

Testing laboratory
Janoshik Analytical
Accreditation
ISO/IEC 17025:2017
Country of synthesis
United States
Manufactured
Jul 7, 2026
Release tested
Jul 16, 2026 (2 months ago)
Retest date
Jul 6, 2028

Assay results

Every line the release panel ran for this lot, with the method, the acceptance criterion and the measured value — not a pass mark alone.

Certificate of analysis — assay results
MethodParameterSpecificationResult
RP-HPLC (UV 214 nm)Purity (area %)≥ 98.0 %99.33 %Pass
LC-MS (ESI+)Identity — observed massConforms to referenceConformsPass
Amino acid analysisNet peptide content≥ 80.0 %88.4 %Pass
Karl FischerWater content≤ 8.0 %2.49 %Pass
Ion chromatographyResidual TFA≤ 1.0 %0.09 %Pass
LAL kinetic chromogenicBacterial endotoxin< 5.0 EU/mg< 0.83 EU/mgPass
USP <71> membrane filtrationSterilityNo growthNo growthPass
Visual / USP <790>AppearanceWhite to off-white cake, free of visible particulatesConformsPass
ICP-MSCopper content (molar ratio Cu:peptide)0.95 – 1.05 : 10.973:1Pass
ICP-MSFree (uncomplexed) copper≤ 0.5 %0.21 %Pass
RP-HPLC (multi-peak resolving gradient)GHK-Cu — purity in finished vial≥ 98.0 %98.48 %Pass
RP-HPLC (multi-peak resolving gradient)BPC-157 — purity in finished vial≥ 98.0 %98.47 %Pass
RP-HPLC (multi-peak resolving gradient)TB-500 — purity in finished vial≥ 98.0 %98.49 %Pass

Handling for this lot

Appearance
Blue lyophilised cake — the copper complex
Storage
-20 °C lyophilised, protected from light. Copper complexes are photosensitive.
Reconstitution
Non-chelating diluent only. Citrate or EDTA buffers will strip copper from the complex and, worse, release free copper that oxidises the other two peptides.

Other lots of GHK-Cu + BPC-157 + TB-500 Blend

Compare batch to batch. Consistency across lots is a stronger signal than any single certificate.

Research use only. This certificate describes material supplied strictly for laboratory research. It is not a drug, food, cosmetic or medical device, has not been evaluated by the FDA, and is not intended for human or veterinary administration of any kind.