Skip to content
Third-party HPLC + mass spec on every lot
Verified — all release criteria met
released

Certificate of analysis

GHK-Cu

Lot CP-GHKCU-2605B · 100 mg

99.46 %

HPLC purity

Spec ≥ 99.0 %

83.3 %

Net peptide content

By amino acid analysis

< 0.60

Endotoxin (EU/mg)

Spec < 5.0 EU/mg

Provenance

Testing laboratory
Colmaric Analyticals
Accreditation
ISO/IEC 17025:2017
Country of synthesis
United States
Manufactured
May 3, 2026
Release tested
May 12, 2026 (5 months ago)
Retest date
May 2, 2028
CAS number
89030-95-5
Molecular formula
C14H24N6O4Cu
Theoretical mass
403.94 Da
Observed mass (LC-MS)
404.07 Da (Δ 0.13 Da)

Assay results

Every line the release panel ran for this lot, with the method, the acceptance criterion and the measured value — not a pass mark alone.

Certificate of analysis — assay results
MethodParameterSpecificationResult
RP-HPLC (UV 214 nm)Purity (area %)≥ 99.0 %99.46 %Pass
LC-MS (ESI+)Identity — observed mass403.94 ± 1.0 Da404.07 DaPass
Amino acid analysisNet peptide content≥ 80.0 %83.3 %Pass
Karl FischerWater content≤ 8.0 %1.52 %Pass
Ion chromatographyResidual TFA≤ 1.0 %0.33 %Pass
LAL kinetic chromogenicBacterial endotoxin< 5.0 EU/mg< 0.60 EU/mgPass
USP <71> membrane filtrationSterilityNo growthNo growthPass
Visual / USP <790>AppearanceWhite to off-white cake, free of visible particulatesConformsPass
ICP-MSCopper content (molar ratio Cu:peptide)0.95 – 1.05 : 11.002:1Pass
ICP-MSFree (uncomplexed) copper≤ 0.5 %0.10 %Pass

Sequence

H-Gly-His-Lys-OH · Cu(II)

Handling for this lot

Appearance
Deep blue lyophilised powder — colour is the copper complex and is expected
Storage
-20 °C lyophilised, protected from light. Copper complexes are photosensitive.
Reconstitution
Use non-chelating diluent. EDTA or citrate buffers will strip the copper and leave you with the free tripeptide.

Other lots of GHK-Cu

Compare batch to batch. Consistency across lots is a stronger signal than any single certificate.

Research use only. This certificate describes material supplied strictly for laboratory research. It is not a drug, food, cosmetic or medical device, has not been evaluated by the FDA, and is not intended for human or veterinary administration of any kind.