Skip to content
Third-party HPLC + mass spec on every lot
Verified — all release criteria met
releasedCurrent lot

Certificate of analysis

Survodutide

Lot CP-SURVOD69-2606A · 5 mg

98.36 %

HPLC purity

Spec ≥ 98.0 %

86.2 %

Net peptide content

By amino acid analysis

< 0.60

Endotoxin (EU/mg)

Spec < 5.0 EU/mg

Provenance

Testing laboratory
Janoshik Analytical
Accreditation
ISO/IEC 17025:2017
Country of synthesis
United States
Manufactured
Jun 18, 2026
Release tested
Jun 27, 2026 (3 months ago)
Retest date
Jun 17, 2028
CAS number
2138731-34-1
Theoretical mass
4737.40 Da
Observed mass (LC-MS)
4737.20 Da (Δ 0.20 Da)

Assay results

Every line the release panel ran for this lot, with the method, the acceptance criterion and the measured value — not a pass mark alone.

Certificate of analysis — assay results
MethodParameterSpecificationResult
RP-HPLC (UV 214 nm)Purity (area %)≥ 98.0 %98.36 %Pass
LC-MS (ESI+)Identity — observed mass4737.40 ± 1.0 Da4737.20 DaPass
Amino acid analysisNet peptide content≥ 80.0 %86.2 %Pass
Karl FischerWater content≤ 8.0 %2.37 %Pass
Ion chromatographyResidual TFA≤ 1.0 %0.26 %Pass
LAL kinetic chromogenicBacterial endotoxin< 5.0 EU/mg< 0.60 EU/mgPass
USP <71> membrane filtrationSterilityNo growthNo growthPass
Visual / USP <790>AppearanceWhite to off-white cake, free of visible particulatesConformsPass

Handling for this lot

Appearance
White lyophilised cake
Storage
-20 °C lyophilised, protected from light
Reconstitution
If working with sensitive cell lines, note the residual TFA figure on the lot certificate and buffer-exchange if required.

Research use only. This certificate describes material supplied strictly for laboratory research. It is not a drug, food, cosmetic or medical device, has not been evaluated by the FDA, and is not intended for human or veterinary administration of any kind.